REDSS Self Supporting Cable
  Remee Products Corporation has enhanced its outside plant fiber-optic product line. Remee's REDSS fiber optic cable is an all-dielectric, self-supporting, loose tube cable. The REDSS cable is designed to take advantage of existing transmission and distribution infrastructures. The use of loose tube cable design is key to providing fiber isolation both during installation and throughout its' service life in all NESC loading conditions. The all-dielectric cable construction eliminates the need for bonding and grounding while the optional track resistant jacket permits installation in high field voltages. The hardware, equipment, and procedures used in the installation of this cable are fundamentally the same as employed by the utility industry.




Part Number

Diam.
mm
(in)

Dynamic Wt. kg/km (lbs./1M)
Maximum Bending Rad. (cm)
(in)
Typical Ultimate Op. Load lbs. / (N) Breaking Strength
lbs.
(N)
80-012-YYY-MBSLNNH3 13.8
(.545)
146
(98)
(35)
14
7005
(1575)
13344
(3000)
80-024-YYY-MBSLNNH3 13.8
(.545)
146
(98)
(35)
14
7005
(1575)
13344
(3000)
80-036-YYY-MBSLNNH3 13.8
(.545)
147
(99)
(35)
14
7005
(1575)
13344
(3000)
80-048-YYY-MBSLNNH3 13.8
(.545)
147
(99)
(35)
14
7005
(1575)
13344
(3000)
80-060-YYY-MBSLNNH3 14.6
(.575)
168
(113)
(35)
14
7561
(1700)
14234
(3200)
80-072-YYY-MBSLNNH3 14.9
(.590)
178
(120)
(38)
15
8896
(2000)
16903
(3800)
80-084-YYY-MBSLNNH3 15.6
(.615)
198
(133)
(38)
15
9341
(2100)
17792
(4000)
80-096-YYY-MBSLNNH3 17.0
(.670)
222
(149)
(43)
17
9786
(2200)
19127
(4300)
80-120-YYY-MBSLNNH3 18.9
(.745)
282
(190)
(48)
19
10675
(2400)
20016
(4500)
80-144-YYY-MBSLNNH3 21.3
(.840)
347
(233)
(53)
21
12010
(2700)
22241
(5000)
   
Crush Resistance (EIA-455-41) 200 N/cm
Impact Resistance (EIA-455-25)
Flexing (EIA-435-104)
   
Min. Bend Radius - Loaded: 20 x O.D.
  Unloaded: 10 x O.D.
Temperature - Operating: -40° to + 70°C
  Storage: -20° to +70C°
   
The values listed herein are nominal. Remee Products Corp. reserves the right to modify them.
   
    NESC Loading Condition (Rule 250B)
  Units Heavy Medium Light
Radial Ice Thickness mm (in.) 12.5 (0.5) 6.5 (0.25) 0 (0)
Horizontal wind pressure Pa (lbf/ft2) 190 (4) 190 (4) 430 (9)
Corresponding wind spd km/hr (mile/hr) 65 (40) 65 (4) 96 (60)

Remee reserves the right to mark all it's cable constructions EITHER U/L or  ETL.


Remee Products Corp. P.O. Box 488, 468 Rte. 17A Florida, NY 10921