Remee Products Corporation
has enhanced its outside plant fiber-optic product line. Remee's
REDSS
fiber optic cable is an all-dielectric, self-supporting, loose tube
cable. The REDSS
cable is designed to take advantage of existing transmission and
distribution infrastructures. The use of loose tube cable design
is key to providing fiber isolation both during installation and
throughout its' service life in all NESC loading conditions. The
all-dielectric cable construction eliminates the need for bonding
and grounding while the optional track resistant jacket permits
installation in high field voltages. The hardware, equipment, and
procedures used in the installation of this cable are fundamentally
the same as employed by the utility industry.
Part
Number
Diam.
mm
(in)
Dynamic Wt. kg/km (lbs./1M)
Maximum
Bending Rad. (cm)
(in)
Typical
Ultimate Op. Load lbs. / (N)
Breaking
Strength
lbs.
(N)
80-012-YYY-MBSLNNH3
13.8
(.545)
146
(98)
(35)
14
7005
(1575)
13344
(3000)
80-024-YYY-MBSLNNH3
13.8
(.545)
146
(98)
(35)
14
7005
(1575)
13344
(3000)
80-036-YYY-MBSLNNH3
13.8
(.545)
147
(99)
(35)
14
7005
(1575)
13344
(3000)
80-048-YYY-MBSLNNH3
13.8
(.545)
147
(99)
(35)
14
7005
(1575)
13344
(3000)
80-060-YYY-MBSLNNH3
14.6
(.575)
168
(113)
(35)
14
7561
(1700)
14234
(3200)
80-072-YYY-MBSLNNH3
14.9
(.590)
178
(120)
(38)
15
8896
(2000)
16903
(3800)
80-084-YYY-MBSLNNH3
15.6
(.615)
198
(133)
(38)
15
9341
(2100)
17792
(4000)
80-096-YYY-MBSLNNH3
17.0
(.670)
222
(149)
(43)
17
9786
(2200)
19127
(4300)
80-120-YYY-MBSLNNH3
18.9
(.745)
282
(190)
(48)
19
10675
(2400)
20016
(4500)
80-144-YYY-MBSLNNH3
21.3
(.840)
347
(233)
(53)
21
12010
(2700)
22241
(5000)
Crush Resistance
(EIA-455-41) 200 N/cm
Impact Resistance
(EIA-455-25)
Flexing
(EIA-435-104)
Min. Bend Radius -
Loaded: 20 x O.D.
Unloaded: 10 x O.D.
Temperature -
Operating: -40° to + 70°C
Storage: -20° to +70C°
The values listed
herein are nominal. Remee Products Corp. reserves the right
to modify them.